SATEL INTEGRA Plus 33
weekly – if the partition is to be armed / disarmed at different times on different days of
the week.
12. Press the
key
.
13. If you have selected the daily variant, the function will allow you at once to program the
arming time, and upon pressing the or key – the disarming time. Upon confirmation
with the
key, you will be brought back to the list of options and functions.
14. If you have selected the weekly variant, you will be brought back to the list of options and
functions, where functions will appear to enable programming of the arming / disarming
time for each day of the week (in the same way as for daily timer).
Programming the value 99:99 means that the partition will not be armed / disarmed.
15. After the arming time has been programmed, an additional function will be displayed,
which allows you to define which arming mode will be activated by the given timer. By
default, the timer activates the full arming mode. If another arming mode is to be
activated, run this function (for the daily timer or individually for each day of the week)
and, using the and keys, select another arming mode. Confirm, using the
key.
16. Having programmed all parameters, press the
key.
17. When a prompt appears, asking you if the changes are to be saved, press the 1 key.
5.13 Zone testing
Within periodic inspections of the security alarm system, the detectors must be checked for
proper functioning. The zone testing function will allow you to do it without triggering the
reaction normally expected on violation, which is of particular importance in case of
permanently armed zones.
1. Enter the code and confirm with the
key
.
2. Using the key, scroll through the menu until you find the TESTS submenu.
3. Press the
key
.
4. Using the key, scroll through the menu until you find the ZONES TEST submenu.
5. Press the
key
.
6. When the NEW function is displayed, press the
key.
7. Select whether burglary zones or fire and technical zones will be tested, and then press
the
key.
8. Select the partitions in which zones will be tested (see: section S
ELECTION FROM THE
MULTIPLE
-CHOICE LIST p. 15).
9. Specify the test duration (maximum 50 minutes) and press the
key.
10. Define, whether violation of a zone is to be signaled by chime in the keypad (the signaling
will be enabled upon pressing any digit key – the symbol will be displayed).
11. Press the
key
. The zone test will start.
Beginning of the zone test in any partition will start the test mode in all ABAX system
wireless devices which are used together with the control panel (the wireless detectors
will signal violations by means of LEDs).
If any detectors with remote LED ON/OFF function are connected to the control panel,
you can switch on the LEDs in them for the test duration (the installer can configure
the control panel so that this will take place automatically at the beginning of the test).
You can terminate the zone test before expiration of the programmed time, using the
FINISH TEST function (TESTS ZONE TEST FINISH TEST). Up to 6 seconds can elapse