Buttons – the button functions are available, if a keyfob has been assigned to the user. It is
possible to assign a zone to a keyfob button or combination of buttons. The zone will be
violated upon pressing the button / combination of buttons. The assigned zone should not
exist physically.
Zone 256 cannot be assigned to any button / combination of buttons.
Events (RX) / Events (ABAX) – if a keyfob has been assigned to the user, it is possible to
define whether pressing the appropriate keyfob button will result in logging an event which
informs that the keyfob has been used.
ABAX confirmation – if an ABAX system keyfob has been assigned to the user, it is
possible to determine the status of which outputs will be presented on the keyfob LEDs on
pressing any button.
Name – individual user name.
5.8.1 User types
The name as used in the keypad is shown in the square brackets. The description includes
only the codes, but the information provided below applies to all identifiers assigned to the
user.
Normal – basic type of user.
One-time [Single] – the user will get one-time access.
Renewable [Time renewable] – the user has access to the system for a defined period of
time. The user validity time should be defined. Before the validity time expires, the control
panel will prompt the user to change the code. After the code has been changed, the
validity time will run from the beginning.
Temporary [Time not renew.] – the user has access to the system for a defined period of
time. The user validity time should be defined. After the validity time expires, the user will
have no access to the system.
Duress – code to be used in hold-up and duress situations. Use it to trigger a silent alarm
and send the event code to the monitoring station.
„Mono” output operating [Mono outputs] – code for control of the MONO
SWITCH type
outputs.
„Bi” output operating [Bi outputs] – code for control of the BI SWITCH type outputs.
Blocking partition [Part.temp.block.] – the code enables access to the armed partitions.
Using the code will block the armed partition(s) (the partition zones will not trigger the
burglary alarm). The blocking time is defined individually for each user within the range
from 1 to 109 minutes. If, however, the time of bypassing for guard round is defined for the
partition and its duration is longer, the blocking will last longer.
Cash machine zones bypassing [Acces.to cash m.] – the code to be used to unblock
access to the cash dispenser (the 24H
CASH MACHINE type zones will be temporarily
bypassed in the partition).
Guard – using this code means having made the round (additionally, it can result in the
partition being temporarily bypassed for the duration of guard round). The installer defines
the modules which are used to confirm making the round and determines the time interval
between successive rounds. If such a user is granted access to the partition, he/she will
have the same possibilities as the NORMAL type user.
Scheduled – the user has access to the system as per the time schedule for a specified
period of time. It is necessary to select the schedule (the schedule is programmed by the
installer) and define the user validity period.