32 User Manual SATEL
7. Press the
key
. The last one of the selected events which occurred in the system will be
displayed.
8. Using the key, scroll through the list of previous events.
In addition to defining the event types to be displayed, the SELECT PART. function can
also be used to indicate the partitions to which the events are to refer.
If the GRADE 3 option is enabled in the system, the installer or administrator can use
the VIEW GRADE3 function instead of the VIEW function. In such a case, the events
selected among those required by the EN 50131 standard for Grade 3 will be
displayed.
5.11.4 Way of presenting events
The following information is shown in the display upper line:
– date and time of event occurrence;
– additional information on the events in shortened form, e.g. number of partition, zone,
user, timer, expander, keypad, etc.
Event description is displayed in the lower line.
If no key is pressed for a few seconds, additional information on the event will be displayed,
e.g. name of partition, zone, user, timer, expander, keypad, etc.. After a few seconds, the
event description will be displayed again, and so on.
Pressing the key enables the manual toggling between description of the event and
additional information on the event.
Pressing the key when the event description is displayed will allow you to see further
additional information on the event, shown in a shortened form.
Using the or key will block the automatic toggling between description of the event and
additional information on the event.
After the list of events has been scrolled through with the use of the or key, the
automatic toggling between description of the event and additional information on the event
will be restored.
5.12 Programming the partition timer
The partition timer automatically arms / disarms the partition.
1. Enter the code and confirm with the
key
.
2. Using the key, scroll through the menu until you find the CHANGE OPTIONS submenu.
3. Press the
key
.
4. Using the key, scroll through the menu until you find the PART. TIMERS function.
5. Press the
key
. The list of partitions will be displayed.
6. Using the and keys, find in the list the partition for which the timer is to be
programmed.
7. Press the
key
.
8. When the ACTIVE option is displayed, make sure it is enabled (the
symbol is displayed
next to the option). If it is not enabled (the
symbol is displayed next to the option), press
any digit key.
9. Using the key, scroll through the menu until you find the TYPE function.
10. Press the
key
.
11. Using the and keys, select the timer type:
everyday – if the partition is to be armed / disarmed at the same time every day;
Komentáře k této Příručce