SATEL INTEGRA Plus 23
5.4.5 Denial of arming
The installer can program the control panel so that the arming procedure could not be
started, if:
– a zone is violated in the partition;
– there is a trouble in the system (including tamper);
– there was a verified alarm.
The keypad will inform you about the refusal to arm by means of a message specifying the
cause for refusal.
If after a verified alarm the arming is impossible, the installer must be called. The
arming will only be possible after the installer intervention (see: description of the
SYSTEM RESET function, p. 16).
Bypassing violated zones when arming
If the arming procedure could not be started, and a message on the display informs you that
there are violated zones, you can review the list of such zones upon pressing the 2 key. To
scroll through the list, use the and keys. Pressing the 4 key will allow you to bypass the
given zone. A message on the display will prompt you to press the 1 key to confirm that the
zone is to be bypassed.
Forced arming
If the arming procedure could not be started, the displayed message can allow of the forced
arming (1=Arm). On pressing the 1 key, the system will be armed despite a violated zone or a
trouble.
5.4.6 Failure of arming procedure
If the installer has enabled the GRADE 3 option, the arming procedure may end in failure. The
system will not be armed, if at the end of the exit delay countdown:
– there is a violated zone in partition which was not violated when the arming procedure
was started;
– there is a trouble which did not exist when the arming procedure was started.
5.4.7 Shortening the exit delay time
If such an option is permitted by the installer, the partition exit delay time may be shortened
upon pressing in turn the 9 and
keys.
5.5 Disarming and alarm clearing
Enter the code and confirm with the
key
(see: section [CODE] – ARMING / DISARMING MENU
p. 10). If only selected partitions are to be disarmed (DISARM SELECTED function), the
partitions should be selected in the same way as when arming the selected partitions.
5.5.1 Alarm clearing without disarming
1. Enter the code and confirm with the
key
.
2. Using the key, scroll through the menu until the CLEAR ALARM function is found.
3. Press the
key
.
Komentáře k této Příručce