- hold down
for 3 sec. to GOTO
selected partition
- hold down for 3 sec. to activate alarm
log viewing
- hold down for 3 sec. to
activate/deactivate CHIME signaling
[
*
] - hold down for 3 sec. to restore basic partition
(GOTO) or to activate
FIRE ALARM
CODE+[
*
] - User Functions:
[CODE][
*
][1] - user access code change
[CODE][
*
][2] - user (code) add
[CODE][
*
][3] - user (code) erase
[CODE][
*
][4] - zone bypass
[CODE][
*
][5] - silent arming
[CODE][
*
][6] - time setting
[CODE][
*
][7] - MONO switch outputs
[CODE][
*
][8] - BI switch outputs
[CODE][
*
][9] - power supply reset
[CODE][
*
][0] - DOWNLOADING start
- hold down for 3 sec. to
activate AUXILIARY ALARM
hold down for 3 sec. to activate
PANIC ALARM
CODE+[#] – arm/disarm partition,
clear alarm
alarm in current partition
system trouble – check by holding
down key
for 3 sec.
on – partition armed,
blinking – exit time countdown
- hold down for 3 sec. to display current
trouble condition
TROUBLE DISPLAY:
1,2,3 - Output 1,2,3 trouble
4 - 230V AC loss
5 - Low battery
6 - Keypad supply fail
7 - Time not set
8 - Printer trouble
9 - Telephone line loss
10 - Problem with transmission to station
11 - Telephone line trouble
12 - Output 4 trouble
all off - System memory fault
LEDs 1
12 (zones state)
ON
- zone violated
OFF
- zone OK
fast blinking
- zone activated alarm (alarm memory)
on, short off every 2 sec. - detector tamper (2EOL zone type)
flashing every 2 sec.
- tamper memory (detector was tampered - 2EOL zone type)
slow blinking
- zone bypassed
- hold down for 3 sec. to activate trouble log viewing.
TROUBLE DISPLAY: LED ON =
1,2,3 - Output 1,2,3 trouble
4 - 230VAC loss
5 - Battery trouble
6 - Keypad power supply trouble
7 - Time not set
8 - Printer trouble
9 - Telephone line loss
10 - Problem with transmission to monitoring station
11 - not used
12 - Output 4 trouble
Komentáře k této Příručce