CA-10 SATEL
19
After calling the function, the control panel generates two short beeps and waits for the
output number key (1-6) to be pressed. The control consists in changing over the status
of the given output to its opposite, i.e. the inactive output gets activated and vice versa.
Provision is made for multiple control of the same output or control of different outputs
of the SWITCH BI type after single calling of the function. Activation of the output is
confirmed by four short and one long beeps, and its deactivation - with three short
beeps. Refusal of control is signaled with two long beeps. The control panel may refuse
control, if the output is not of the SWITCH BI type or if it belongs to another partition.
Pressing the keys [#] or [
*
] will end the function. The control panel will automatically
terminate the function if none of the outputs is of the SWITCH BI type, or if no key on
the keypad is depressed for 40 seconds.
The function is accessible to the master user, as well as to the users with authority
levels 1 and 6.
Power supply reset [CODE][
*
][9]
This function is used to operate special detectors equipped with individual on/off
memory which is cleared by powering down the system (e.g., smoke detectors, broken
glass detectors). The function temporarily disconnects power supply to such detectors
(on „RESET power supply” outputs).
The function is available to the master user and users with authority level 1.
Telephone DOWNLOADING start [CODE][
*
][0]
This function can be activated by the master user and the users with authority level 1. It
starts the control panel - service PC telephone connection. The function enables the
panel - PC telephone communication, when the possibility to initiate connection from the
PC computer is blocked.
On activating the function the panel engages the telephone line and connects to the
service computer. If the panel fails to establish connection, it will make four more
attempts to get through. During the data exchange the telephone line will be busy. The
service can temporarily suspend the connection to free the telephone line and, after
some time, call back the panel to continue data exchange. The installer should make
users aware of the procedure so that they do not answer the incoming calls and allow
re-establishing and correct completion of the transmission.
Viewing events log (additional function in the LCD keypad)
On activating the function, the users can view the memory log in which all the events
are recorded in detail. The keys enable scrolling through the list of events, and the
keys make it possible to get extra information: zone descriptions, partition and user
names.