10 ETHM-1 Plus SATEL
Port [DloadX port] – number of the TCP port used for communication with the DLOADX
program. You can enter values from 1 to 65535. The value must be different from that
entered for the other ports. Default value: 7090.
DLOADX server [DloadX] – address of the computer running the DLOADX program. If the
computer is not in the same local network, it must be a public address. You can enter
either the IP address or the domain name.
DloadX key [DloadX key] – a string of up to 12 alphanumeric characters (digits, letters and
special characters) defining the key for data encryption during communication with the
DLOADX program.
Fig. 6. D
LOADX program: parameters and options of the ETHM-1 Plus module connected to
VERSA control panel.
PING test
Address to test [PING] – address of the device to which a ping command to test
communication is to be sent by the module. You can enter IP address or domain name.
Period [PING period] – the time interval between successive communication tests using the
ping command. If value 0 is programmed, the communication test is disabled.
Tries no. before trouble [PING tries] – the number of failed communication tests (the
module received no answer to the ping command sent), after which the trouble will be
reported. If value 0 is programmed, the communication test is disabled.