2 SMET-256 SATEL
Explanations for Fig. 1:
1 – LED indicators:
PWRpower indicator – ON when power supply is connected
STstatus indicator:
ON – RS-232 port working in RC4000 VISONIC, SurGuard (MLR2/MLR2E)
or RSM-02 receiver emulation mode
blinking fast – replacement of converter firmware
momentarily dimming – wrong converter configuration data (also on the
first-time run, before configuration)
lights up momentarily – RS-232 port available for communication with the
computer
RIringing indicator – ON when the converter is calling the reporting station
OHreporting station connection indicator:
ON – connection to the monitoring station
blinking – timeout of reporting station connection (converter is sending no
more data)
WThandshake / kiss-off indicator:
ON – waiting for handshake / kiss-off signal from the monitoring station
blinking – there are data to be sent, but there is no kiss-off signal from the
monitoring station
ERRtrouble indicator:
blinking fast – no Ethernet network cable
1 short blink, followed by a pause – the station is not answering the call
2 short blinks, followed by a pause – the station went off-hook, but no
handshake / kiss-off signal was received
3 short blinks, followed by a pause – the station hung up before all data were
sent
2 - RJ-45 socket for connection of the Ethernet network cable. Use the same cable as the
one for connecting computer to the network. The socket has two built-in indicator LEDs.
The green one indicates connection to the network and data transfer, and the yellow
one – negotiated transmission rate (ON: 100Mb; OFF: 10Mb).
3 - RJ socket (6P2C) for connection of the telephone cable, connecting the converter to
the monitoring station.
4 - power socket for connection of the 12 V DC power supply unit . The power
supply current capacity must be at least 750 mA.
5 - DB-9F socket (RS-232 port) for communication with the reporting station (emulation of
RC4000 VISONIC, SurGuard (MLR2/MLR2E) and RSM-02 receiver) or the computer.
3. CONVERTER INSTALLATION
1. Connect the Ethernet network cable to the RJ-45 socket.
2. Using telephone cable, connect the converter RJ socket with the reporting station
(emulation of analog telephone line), or connect the converter DB-9 socket with the
reporting station RS-232 port (emulation of RC4000 VISONIC, SurGuard (MLR2/MLR2E)
and RSM-02 receiver).
3. Connect power supply.